Aktive Carbon Filter pou Tretman Dlo Endistriyèl

Aktive Carbon Filter pou Tretman Dlo Endistriyèl
Detay yo:
Nan sistèm tretman dlo endistriyèl yo, tras òganik, rès klò, ak dezenfeksyon byproducts ka move manbràn, degrade rezin, korode ekipman, ak konpwomi bon jan kalite pwodwi. Filtè aktive kabòn nou an pou tretman dlo endistriyèl yo bay gwo -kapasite, kontinyèl-adsorpsyon koule lè l sèvi avèk prim granulaire aktive kabòn (GAC) nan ASME-kode oswa NSF/ANSI 61-sètifye veso presyon. Enjenyè pou fyab nan plant elektrik, raffineries, liy manje ak bwason, fab semi-conducteurs, ak enstalasyon pharmaceutique, sistèm nou yo redwi klò a.<0.1 ppm, remove VOCs and THMs, and protect downstream critical assets—with full automation and global engineering support.
Voye rechèch
Rale dosye
Dekri teren
Karakteristik teknik

Filtè Kabòn Aktive Pou Tretman Dlo Endistriyèl - Gwo-Sistèm GAC devwa pou klò, VOCs ak retire òganik nan pwosesis, chodyè, ak RO Feedwater

 

Nan sistèm tretman dlo endistriyèl yo, tras òganik, rès klò, ak dezenfeksyon byproducts ka move manbràn, degrade rezin, korode ekipman, ak konpwomi bon jan kalite pwodwi. Filtè aktive kabòn nou an pou tretman dlo endistriyèl yo bay gwo -kapasite, kontinyèl-adsorpsyon koule lè l sèvi avèk prim granulaire aktive kabòn (GAC) nan ASME-kode oswa NSF/ANSI 61-sètifye veso presyon. Enjenyè pou fyab nan plant elektrik, raffineries, liy manje ak bwason, fab semi-conducteurs, ak enstalasyon pharmaceutique, sistèm nou yo redwi klò a.<0.1 ppm, remove VOCs and THMs, and protect downstream critical assets-with full automation and global engineering support.

 

Activated Carbon Filter For Industrial Water Treatment

 

Poukisa Endistriyèl-Filtè Kabòn Aktive Klas Se Pa-Negosyab

 

Filtè kabòn rezidansyèl estanda yo manke pwofondè kabann, distribisyon koule, ak kalite medya ki nesesè pou demand endistriyèl yo. Enjenyè filtè kabòn aktive endistriyèl nou yo karakteristik:
* Optimize EBCT (Tan kontak kabann vid):5-15 minit-ki asire absòpsyon konplè kloramin, pestisid, ak òganik sentetik
* Gwo-pite GAC Media:Koki kokoye (sann ki ba) oswa chabon-ki baze sou (gwo kapasite), ak nimewo yòd ki pi gran pase oswa egal a 900 mg/g
* Sistèm Precision Underdrain:Distribisyon koule inifòm anpeche kanalizasyon ak maksimize itilizasyon kabòn
* Backwash otomatik:Retire patikil ki kwense, rklasifye kabann medya yo, pwolonje lavi sèvis
* Redondans évolutive:Duplex oswa N+1 sistèm glisman asire operasyon 24/7 pandan antretyen
* NSF/ANSI 61 & 42 sètifye:Verifye sekirite ak pèfòmans pou dlo potab ak pwosesis dlo

 

Aplikasyon endistriyèl kritik

 

* Osmoz ranvèse (RO) Pretretman:Retire klò ki soksid manbràn poliamid-pwolonje lavi a 2-3 fwa
* Chodyè & Refwadisman Tower Feedwater:Elimine òganik ki lakòz kimen, transfè, ak kwasans mikrobyolojik
* Manje ak bwason:Asire klò-dlo engredyan gratis pou brase, bwason gaz, ak pwosesis letye
* Famasetik:Satisfè egzijans pretretman Dlo Pirifye (PW) USP pou kontwòl TOC
* Semiconductors & Elektwonik:Diminye TOC nan dlo ultrapure (UPW) alimentation pou<50 ppb
* Jenerasyon pouvwa:Poli kondansasyon ak dlo makiyaj pou anpeche korozyon turbine
* Chimik ak petwochimik:Trete dlo pwosesis ak dlo ize pou konfòmite VOC

 

Done teknik

 

Modèl

Dyamèt tank la

(mm)

Total Wotè

(mm)

Dyamèt Inlet/Outlet

(mm)

Kapasite

(m3/h)

Pwa sab

(tòn)

Aktive Kabòn

(tòn)

CY-MMF-500

500

2350

DN32

2

0.39

0.11

CY-MMF-600

600

2380

DN32

3

0.56

0.16

CY-MMF-700

700

2400

DN40

4

0.76

0.22

CY-MMF-800

800

2400

DN40

5

1

0.3

CY-MMF-900

900

2500

DN50

6

1.3

0.36

CY-MMF-1000

1000

2600

DN50

8

1.6

0.45

CY-MMF-1200

1200

2700

DN65

11

2.3

0.65

CY-MMF-1400

1400

2800

DN65

15

3

0.86

CY-MMF-1500

1500

2850

DN65

18

3.5

1

CY-MMF-1600

1600

2900

DN80

20

4

1.2

CY-MMF-1800

1800

3000

DN80

25

5

1.5

CY-MMF-2000

2000

3100

DN100

30

6

1.8

CY-MMF-2200

2200

3180

DN100

38

7.5

2.2

CY-MMF-2400

2400

3330

DN100

45

9

2.5

CY-MMF-2500

2500

3380

DN100

50

9.7

2.8

CY-MMF-2600

2600

3430

DN125

55

10

3

CY-MMF-2800

2800

3530

DN125

60

12.5

3.5

CY-MMF-3000

3000

3630

DN125

70~80

14

4

CY-MMF-3200

3200

3730

DN150

80~100

14

4.5

 

Details of Activated Carbon Filter

 

FAQ

 

Q1: Ki diferans ki genyen ant estanda GAC ​​ak kabòn katalitik?

A: GAC estanda efektivman retire klò gratis ak anpil VOC men reyaji tou dousman ak kloramin (NH₂Cl), ki mennen nan lavi kout.
Yo trete kabòn katalitik espesyalman pou akselere dekonpozisyon kloramin nan klori inofansif ak gaz nitwojèn -ofri 3-5 fwa pi long lavi sèvis nan dlo kloramine. Li tou efikasman retire sulfid idwojèn (H₂S).
Nou rekòmande katalitik kabòn pou nenpòt sistèm ki sèvi ak dlo minisipal kloramine.

 

Q2: Èske filtè kabòn ou ka okipe gwo fè oswa Manganèz?

A: Chabon aktive pa retire fè fonn oswa Manganèz. An reyalite, fè ka move sifas kabòn lan epi redwi kapasite adsorption. Si dlo w genyen Fe/Mn:
1. Premye oksidasyon ak klò, ozòn, oswa piki lè
2. Lè sa a, enstale yon filtè doub -medya (egzanp, sab vèt oswa sab) anlè pou retire metal presipite.
3. Finalman, sèvi ak filtè kabòn pou retire òganik/klò
Nou desine tren pre-tretman entegre pou dlo konplike.

 

Q3: Ki jan ou gwosè yon filtè kabòn endistriyèl?

A: Dimansyon depann sou twa faktè:
1. Pousantaj koule (GPM oswa m³ / h)
2. Kalite ak konsantrasyon kontaminan (pa egzanp, 2 ppm klò kont . 0.1 ppm PFOA)
3. EBCT obligatwa (anjeneral 5-10 min pou klò; 10-15 min pou kloramin/VOC)
→ Nou kalkile volim kabann=Flow × EBCT
Egzanp: 100 GPM × 10 min=1, 000 galon kabann kabòn ≈ 36" dyamèt × 48" pwofondè kabann
Voye nou rapò sou dlo ou a-n ​​ap bay yon fèy gwosè detaye gratis.

 

 

Baj popilè: filtre kabòn aktive pou tretman dlo endistriyèl, Lachin filtre kabòn aktive pou manifaktirè tretman dlo endistriyèl, Swèd, faktori

Voye rechèch